Full Quantification of Left Ventricle via Deep Multitask Learning Network Respecting Intra- and Inter-Task Relatedness
June 06, 2017 ยท Declared Dead ยท ๐ International Conference on Medical Image Computing and Computer-Assisted Intervention
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Wufeng Xue, Andrea Lum, Ashley Mercado, Mark Landis, James Warringto, Shuo Li
arXiv ID
1706.01912
Category
cs.CV: Computer Vision
Citations
69
Venue
International Conference on Medical Image Computing and Computer-Assisted Intervention
Last Checked
3 months ago
Abstract
Cardiac left ventricle (LV) quantification is among the most clinically important tasks for identification and diagnosis of cardiac diseases, yet still a challenge due to the high variability of cardiac structure and the complexity of temporal dynamics. Full quantification, i.e., to simultaneously quantify all LV indices including two areas (cavity and myocardium), six regional wall thicknesses (RWT), three LV dimensions, and one cardiac phase, is even more challenging since the uncertain relatedness intra and inter each type of indices may hinder the learning procedure from better convergence and generalization. In this paper, we propose a newly-designed multitask learning network (FullLVNet), which is constituted by a deep convolution neural network (CNN) for expressive feature embedding of cardiac structure; two followed parallel recurrent neural network (RNN) modules for temporal dynamic modeling; and four linear models for the final estimation. During the final estimation, both intra- and inter-task relatedness are modeled to enforce improvement of generalization: 1) respecting intra-task relatedness, group lasso is applied to each of the regression tasks for sparse and common feature selection and consistent prediction; 2) respecting inter-task relatedness, three phase-guided constraints are proposed to penalize violation of the temporal behavior of the obtained LV indices. Experiments on MR sequences of 145 subjects show that FullLVNet achieves high accurate prediction with our intra- and inter-task relatedness, leading to MAE of 190mm$^2$, 1.41mm, 2.68mm for average areas, RWT, dimensions and error rate of 10.4\% for the phase classification. This endows our method a great potential in comprehensive clinical assessment of global, regional and dynamic cardiac function.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
๐ Similar Papers
In the same crypt โ Computer Vision
๐
๐
Old Age
๐
๐
Old Age
Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks
R.I.P.
๐ป
Ghosted
You Only Look Once: Unified, Real-Time Object Detection
๐
๐
Old Age
SSD: Single Shot MultiBox Detector
๐
๐
Old Age
Squeeze-and-Excitation Networks
R.I.P.
๐ป
Ghosted
Rethinking the Inception Architecture for Computer Vision
Died the same way โ ๐ป Ghosted
R.I.P.
๐ป
Ghosted
Language Models are Few-Shot Learners
R.I.P.
๐ป
Ghosted
PyTorch: An Imperative Style, High-Performance Deep Learning Library
R.I.P.
๐ป
Ghosted
XGBoost: A Scalable Tree Boosting System
R.I.P.
๐ป
Ghosted