Fully Convolutional Networks for Automated Segmentation of Abdominal Adipose Tissue Depots in Multicenter Water-Fat MRI

June 26, 2018 Β· Declared Dead Β· πŸ› Magnetic Resonance in Medicine

πŸ‘» CAUSE OF DEATH: Ghosted
No code link whatsoever

"No code URL or promise found in abstract"

Evidence collected by the PWNC Scanner

Authors Taro Langner, Anders HedstrΓΆm, Katharina MΓΆrwald, Daniel Weghuber, Anders Forslund, Peter Bergsten, HΓ₯kan AhlstrΓΆm, Joel Kullberg arXiv ID 1807.03122 Category cs.CV: Computer Vision Citations 48 Venue Magnetic Resonance in Medicine Last Checked 6 months ago
Abstract
Purpose: An approach for the automated segmentation of visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) in multicenter water-fat MRI scans of the abdomen was investigated, using two different neural network architectures. Methods: The two fully convolutional network architectures U-Net and V-Net were trained, evaluated and compared on the water-fat MRI data. Data of the study Tellus with 90 scans from a single center was used for a 10-fold cross-validation in which the most successful configuration for both networks was determined. These configurations were then tested on 20 scans of the multicenter study beta-cell function in JUvenile Diabetes and Obesity (BetaJudo), which involved a different study population and scanning device. Results: The U-Net outperformed the used implementation of the V-Net in both cross-validation and testing. In cross-validation, the U-Net reached average dice scores of 0.988 (VAT) and 0.992 (SAT). The average of the absolute quantification errors amount to 0.67% (VAT) and 0.39% (SAT). On the multi-center test data, the U-Net performs only slightly worse, with average dice scores of 0.970 (VAT) and 0.987 (SAT) and quantification errors of 2.80% (VAT) and 1.65% (SAT). Conclusion: The segmentations generated by the U-Net allow for reliable quantification and could therefore be viable for high-quality automated measurements of VAT and SAT in large-scale studies with minimal need for human intervention. The high performance on the multicenter test data furthermore shows the robustness of this approach for data of different patient demographics and imaging centers, as long as a consistent imaging protocol is used.
Community shame:
Not yet rated
Community Contributions

Found the code? Know the venue? Think something is wrong? Let us know!

πŸ“œ Similar Papers

In the same crypt β€” Computer Vision

πŸŒ… πŸŒ… Old Age

Fast R-CNN

Ross Girshick

cs.CV πŸ› ICCV πŸ“š 27.7K cites 11 years ago

Died the same way β€” πŸ‘» Ghosted