autoTICI: Automatic Brain Tissue Reperfusion Scoring on 2D DSA Images of Acute Ischemic Stroke Patients
October 03, 2020 Β· Declared Dead Β· π IEEE Transactions on Medical Imaging
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Ruisheng Su, Sandra A. P. Cornelissen, Matthijs van der Sluijs, Adriaan C. G. M. van Es, Wim H. van Zwam, Diederik W. J. Dippel, Geert Lycklama, Pieter Jan van Doormaal, Wiro J. Niessen, Aad van der Lugt, Theo van Walsum
arXiv ID
2010.01432
Category
eess.IV: Image & Video Processing
Cross-listed
cs.CV
Citations
32
Venue
IEEE Transactions on Medical Imaging
Last Checked
6 months ago
Abstract
The Thrombolysis in Cerebral Infarction (TICI) score is an important metric for reperfusion therapy assessment in acute ischemic stroke. It is commonly used as a technical outcome measure after endovascular treatment (EVT). Existing TICI scores are defined in coarse ordinal grades based on visual inspection, leading to inter- and intra-observer variation. In this work, we present autoTICI, an automatic and quantitative TICI scoring method. First, each digital subtraction angiography (DSA) acquisition is separated into four phases (non-contrast, arterial, parenchymal and venous phase) using a multi-path convolutional neural network (CNN), which exploits spatio-temporal features. The network also incorporates sequence level label dependencies in the form of a state-transition matrix. Next, a minimum intensity map (MINIP) is computed using the motion corrected arterial and parenchymal frames. On the MINIP image, vessel, perfusion and background pixels are segmented. Finally, we quantify the autoTICI score as the ratio of reperfused pixels after EVT. On a routinely acquired multi-center dataset, the proposed autoTICI shows good correlation with the extended TICI (eTICI) reference with an average area under the curve (AUC) score of 0.81. The AUC score is 0.90 with respect to the dichotomized eTICI. In terms of clinical outcome prediction, we demonstrate that autoTICI is overall comparable to eTICI.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β Image & Video Processing
R.I.P.
π»
Ghosted
π
π
The Cartographer
Deep Learning for Hyperspectral Image Classification: An Overview
R.I.P.
π»
Ghosted
U-Net and its variants for medical image segmentation: theory and applications
R.I.P.
π»
Ghosted
Algorithm Unrolling: Interpretable, Efficient Deep Learning for Signal and Image Processing
R.I.P.
π
404 Not Found
Lightweight Image Super-Resolution with Information Multi-distillation Network
R.I.P.
π»
Ghosted
Deep Learning on Image Denoising: An overview
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted