Deep Learning Based Classification of Unsegmented Phonocardiogram Spectrograms Leveraging Transfer Learning
December 15, 2020 ยท Declared Dead ยท ๐ Physiological Measurement
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Kaleem Nawaz Khan, Faiq Ahmad Khan, Anam Abid, Tamer Olmez, Zumray Dokur, Amith Khandakar, Muhammad E. H. Chowdhury, Muhammad Salman Khan
arXiv ID
2012.08406
Category
cs.LG: Machine Learning
Cross-listed
cs.AI
Citations
50
Venue
Physiological Measurement
Last Checked
5 months ago
Abstract
Cardiovascular diseases (CVDs) are the main cause of deaths all over the world. Heart murmurs are the most common abnormalities detected during the auscultation process. The two widely used publicly available phonocardiogram (PCG) datasets are from the PhysioNet/CinC (2016) and PASCAL (2011) challenges. The datasets are significantly different in terms of the tools used for data acquisition, clinical protocols, digital storages and signal qualities, making it challenging to process and analyze. In this work, we have used short-time Fourier transform (STFT) based spectrograms to learn the representative patterns of the normal and abnormal PCG signals. Spectrograms generated from both the datasets are utilized to perform three different studies: (i) train, validate and test different variants of convolutional neural network (CNN) models with PhysioNet dataset, (ii) train, validate and test the best performing CNN structure on combined PhysioNet-PASCAL dataset and (iii) finally, transfer learning technique is employed to train the best performing pre-trained network from the first study with PASCAL dataset. We propose a novel, less complex and relatively light custom CNN model for the classification of PhysioNet, combined and PASCAL datasets. The first study achieves an accuracy, sensitivity, specificity, precision and F1 score of 95.4%, 96.3%, 92.4%, 97.6% and 96.98% respectively while the second study shows accuracy, sensitivity, specificity, precision and F1 score of 94.2%, 95.5%, 90.3%, 96.8% and 96.1% respectively. Finally, the third study shows a precision of 98.29% on the noisy PASCAL dataset with transfer learning approach. All the three proposed approaches outperform most of the recent competing studies by achieving comparatively high classification accuracy and precision, which make them suitable for screening CVDs using PCG signals.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
๐ Similar Papers
In the same crypt โ Machine Learning
๐ฎ
๐ฎ
The Ethereal
๐ฎ
๐ฎ
The Ethereal
Continuous control with deep reinforcement learning
๐
๐
Old Age
Model-Agnostic Meta-Learning for Fast Adaptation of Deep Networks
๐
๐
Old Age
Soft Actor-Critic: Off-Policy Maximum Entropy Deep Reinforcement Learning with a Stochastic Actor
๐
๐
Old Age
SGDR: Stochastic Gradient Descent with Warm Restarts
๐ฎ
๐ฎ
The Ethereal
Asynchronous Methods for Deep Reinforcement Learning
Died the same way โ ๐ป Ghosted
R.I.P.
๐ป
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
๐ป
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
๐ป
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
๐ป
Ghosted