Robust R-Peak Detection in Low-Quality Holter ECGs using 1D Convolutional Neural Network
December 29, 2020 Β· Declared Dead Β· π IEEE Transactions on Biomedical Engineering
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Muhammad Uzair Zahid, Serkan Kiranyaz, Turker Ince, Ozer Can Devecioglu, Muhammad E. H. Chowdhury, Amith Khandakar, Anas Tahir, Moncef Gabbouj
arXiv ID
2101.01666
Category
eess.SP: Signal Processing
Cross-listed
cs.CV,
cs.LG
Citations
72
Venue
IEEE Transactions on Biomedical Engineering
Last Checked
5 months ago
Abstract
Noise and low quality of ECG signals acquired from Holter or wearable devices deteriorate the accuracy and robustness of R-peak detection algorithms. This paper presents a generic and robust system for R-peak detection in Holter ECG signals. While many proposed algorithms have successfully addressed the problem of ECG R-peak detection, there is still a notable gap in the performance of these detectors on such low-quality ECG records. Therefore, in this study, a novel implementation of the 1D Convolutional Neural Network (CNN) is used integrated with a verification model to reduce the number of false alarms. This CNN architecture consists of an encoder block and a corresponding decoder block followed by a sample-wise classification layer to construct the 1D segmentation map of R- peaks from the input ECG signal. Once the proposed model has been trained, it can solely be used to detect R-peaks possibly in a single channel ECG data stream quickly and accurately, or alternatively, such a solution can be conveniently employed for real-time monitoring on a lightweight portable device. The model is tested on two open-access ECG databases: The China Physiological Signal Challenge (2020) database (CPSC-DB) with more than one million beats, and the commonly used MIT-BIH Arrhythmia Database (MIT-DB). Experimental results demonstrate that the proposed systematic approach achieves 99.30% F1-score, 99.69% recall, and 98.91% precision in CPSC-DB, which is the best R-peak detection performance ever achieved. Compared to all competing methods, the proposed approach can reduce the false-positives and false-negatives in Holter ECG signals by more than 54% and 82%, respectively. Results also demonstrate similar or better performance than most competing algorithms on MIT-DB with 99.83% F1-score, 99.85% recall, and 99.82% precision.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β Signal Processing
R.I.P.
π»
Ghosted
π
π
The Cartographer
1D Convolutional Neural Networks and Applications: A Survey
R.I.P.
π»
Ghosted
Wireless Communications with Reconfigurable Intelligent Surface: Path Loss Modeling and Experimental Measurement
π
π
The Cartographer
Accessing From The Sky: A Tutorial on UAV Communications for 5G and Beyond
R.I.P.
π»
Ghosted
6G Wireless Systems: Vision, Requirements, Challenges, Insights, and Opportunities
R.I.P.
π»
Ghosted
A New Wireless Communication Paradigm through Software-controlled Metasurfaces
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted