IMJENSE: Scan-specific Implicit Representation for Joint Coil Sensitivity and Image Estimation in Parallel MRI
November 21, 2023 Β· Declared Dead Β· π IEEE Transactions on Medical Imaging
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Ruimin Feng, Qing Wu, Jie Feng, Huajun She, Chunlei Liu, Yuyao Zhang, Hongjiang Wei
arXiv ID
2311.12892
Category
eess.IV: Image & Video Processing
Cross-listed
cs.CV,
cs.LG,
physics.med-ph
Citations
45
Venue
IEEE Transactions on Medical Imaging
Last Checked
6 months ago
Abstract
Parallel imaging is a commonly used technique to accelerate magnetic resonance imaging (MRI) data acquisition. Mathematically, parallel MRI reconstruction can be formulated as an inverse problem relating the sparsely sampled k-space measurements to the desired MRI image. Despite the success of many existing reconstruction algorithms, it remains a challenge to reliably reconstruct a high-quality image from highly reduced k-space measurements. Recently, implicit neural representation has emerged as a powerful paradigm to exploit the internal information and the physics of partially acquired data to generate the desired object. In this study, we introduced IMJENSE, a scan-specific implicit neural representation-based method for improving parallel MRI reconstruction. Specifically, the underlying MRI image and coil sensitivities were modeled as continuous functions of spatial coordinates, parameterized by neural networks and polynomials, respectively. The weights in the networks and coefficients in the polynomials were simultaneously learned directly from sparsely acquired k-space measurements, without fully sampled ground truth data for training. Benefiting from the powerful continuous representation and joint estimation of the MRI image and coil sensitivities, IMJENSE outperforms conventional image or k-space domain reconstruction algorithms. With extremely limited calibration data, IMJENSE is more stable than supervised calibrationless and calibration-based deep-learning methods. Results show that IMJENSE robustly reconstructs the images acquired at 5$\mathbf{\times}$ and 6$\mathbf{\times}$ accelerations with only 4 or 8 calibration lines in 2D Cartesian acquisitions, corresponding to 22.0% and 19.5% undersampling rates. The high-quality results and scanning specificity make the proposed method hold the potential for further accelerating the data acquisition of parallel MRI.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β Image & Video Processing
R.I.P.
π»
Ghosted
π
π
The Cartographer
Deep Learning for Hyperspectral Image Classification: An Overview
R.I.P.
π»
Ghosted
U-Net and its variants for medical image segmentation: theory and applications
R.I.P.
π»
Ghosted
Algorithm Unrolling: Interpretable, Efficient Deep Learning for Signal and Image Processing
R.I.P.
π
404 Not Found
Lightweight Image Super-Resolution with Information Multi-distillation Network
R.I.P.
π»
Ghosted
Deep Learning on Image Denoising: An overview
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted