Seeing Clearly and Deeply: An RGBD Imaging Approach with a Bio-inspired Monocentric Design

October 29, 2025 ยท Declared Dead ยท ๐Ÿ› arXiv.org

๐Ÿ“œ CAUSE OF DEATH: Death by README
Repo has only a README

Repo contents: README.md

Authors Zongxi Yu, Xiaolong Qian, Shaohua Gao, Qi Jiang, Yao Gao, Kailun Yang, Kaiwei Wang arXiv ID 2510.25314 Category cs.CV: Computer Vision Cross-listed cs.RO, eess.IV, physics.optics Citations 0 Venue arXiv.org Repository https://github.com/ZongxiYu-ZJU/BMI โญ 1 Last Checked 1 month ago
Abstract
Achieving high-fidelity, compact RGBD imaging presents a dual challenge: conventional compact optics struggle with RGB sharpness across the entire depth-of-field, while software-only Monocular Depth Estimation (MDE) is an ill-posed problem reliant on unreliable semantic priors. While deep optics with elements like DOEs can encode depth, they introduce trade-offs in fabrication complexity and chromatic aberrations, compromising simplicity. To address this, we first introduce a novel bio-inspired all-spherical monocentric lens, around which we build the Bionic Monocentric Imaging (BMI) framework, a holistic co-design. This optical design naturally encodes depth into its depth-varying Point Spread Functions (PSFs) without requiring complex diffractive or freeform elements. We establish a rigorous physically-based forward model to generate a synthetic dataset by precisely simulating the optical degradation process. This simulation pipeline is co-designed with a dual-head, multi-scale reconstruction network that employs a shared encoder to jointly recover a high-fidelity All-in-Focus (AiF) image and a precise depth map from a single coded capture. Extensive experiments validate the state-of-the-art performance of the proposed framework. In depth estimation, the method attains an Abs Rel of 0.026 and an RMSE of 0.130, markedly outperforming leading software-only approaches and other deep optics systems. For image restoration, the system achieves an SSIM of 0.960 and a perceptual LPIPS score of 0.082, thereby confirming a superior balance between image fidelity and depth accuracy. This study illustrates that the integration of bio-inspired, fully spherical optics with a joint reconstruction algorithm constitutes an effective strategy for addressing the intrinsic challenges in high-performance compact RGBD imaging. Source code will be publicly available at https://github.com/ZongxiYu-ZJU/BMI.
Community shame:
Not yet rated
Community Contributions

Found the code? Know the venue? Think something is wrong? Let us know!

๐Ÿ“œ Similar Papers

In the same crypt โ€” Computer Vision

Died the same way โ€” ๐Ÿ“œ Death by README