TriDP-PTM: a three-stage distortion-perception tradeoff guides the pre-training model for radar cardiac sensing

May 25, 2026 ยท Grace Period ยท + Add venue

โณ Grace Period
This paper is less than 90 days old. We give authors time to release their code before passing judgment.
Authors Jinye Li, Aidong Men, Yang Liu, Qingchao Chen arXiv ID 2605.25725 Category cs.CV: Computer Vision Citations 0
Abstract
Cardiovascular diseases (CVDs) remain a leading cause of death globally, necessitating continuous, accurate non-invasive cardiac monitoring. While non-contact radar-based approaches show great promise, they often employ a single "distortion-driven" or "perception-driven" paradigm, frequently facing a trade-off between "low distortion but weak semantic information" and "high perceptual fidelity but poor interpretability." To address this, we propose a Three-stage Distortion-Perception Pre-Training Model (TriDP-PTM), a radar-based multi-scale fusion dual-path framework that systematically compares the "direct radar-to-task" path against an "indirect radar-to-ECG-to-task" path. By integrating an ECG generator with a feature discriminator to form a composite loss function, our approach effectively incorporates medical priors - such as ECG morphology and rhythm - into downstream tasks. Through empirical analysis, we reveal that this trade-off manifests in three distinct phases (Positive-Sum, Coopetitive, and Negative-Sum), showing optimal downstream clinical accuracy typically emerges in the coopetitive stage. Extensive experiments on a dataset involving 30 subjects across 5 physiological states reveal that the indirect path consistently outperforms the direct path in diverse tasks, achieving 0.80 mean IoU in waveform segmentation, 98.3% average classification accuracy across four tasks, and a 56% MAE reduction in blood pressure regression compared to the strongest baselines. These findings validate our framework and indicate that, within the indirect radar-to-ECG pathway, appropriately weighting distortion and perception losses to operate in the coopetitive regime is critical for achieving both clinically interpretable ECG morphology and strong downstream accuracy in non-contact cardiac monitoring.
Community shame:
Not yet rated
Community Contributions

Found the code? Know the venue? Think something is wrong? Let us know!

๐Ÿ“œ Similar Papers

In the same crypt โ€” Computer Vision

๐ŸŒ… ๐ŸŒ… Old Age

Fast R-CNN

Ross Girshick

cs.CV ๐Ÿ› ICCV ๐Ÿ“š 27.7K cites 11 years ago